Checkline DT-209X Bedienungsanleitung

Stöbern Sie online oder laden Sie Bedienungsanleitung nach Messgeräte Checkline DT-209X herunter. Checkline DT-209X User Manual Benutzerhandbuch

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken

Inhaltsverzeichnis

Seite 2

6FULL Full memory indicator (the unit cannot store additional data) CCCCC Clear data from memory. Holding memory button for 5 seconds will clear s

Seite 3 - Table of Contents

7 Measurement Mode The Measurement Mode is changed with the Measurement Mode Selector switch. There are three basic settings USB, Standard and

Seite 4

8Average mode • The max, min, average, last and time of measurement can be stored in memory via power button. • The unit can store a maximum of 30

Seite 5

9Average Mode USB Mode Online measurements, software controlled programs can run and take measurements while the

Seite 6 - Measurement

10Measuring Methods Rotational speed measurement (Contact RPM) Example: RPM measurement using the cone tip for motor rotation. The contact adapt

Seite 7 - Rotation Speed

11Three decimal points will flash on the center of the display when the tachometer is out of range. Speed and Length Measurements Example: Length me

Seite 8 - For rotational

12Typical measurement update is 1 second. (Using the software the update time can be adjusted as fast as 0.5 second). Things to Remember The rub

Seite 9

13 CAUTION: Do not look into the laser beam opening while in operation. Staring into the laser beam can result to eye damage. The power switch i

Seite 10 - rEAdy

14 Pressing the Power Switch it will show the memory block number where readings will be stored. The block number will flash for a few seconds. (Me

Seite 11

15The memory location where the measurement will be stored is shown on the Unit and Measurement section of the LCD display. (“M” followed by the num

Seite 12

Thank you for your purchase of this Tachometer Product. This manual explains how to operate your equipment safely and correctly. The manual covers

Seite 13

162. Average Mode Average mode is displayed on the LCD screen Pushing the Power Switch will show the memory block number where reading

Seite 14

17 Releasing the Power Switch will trigger the auto shut off feature to activate. 3. USB Mode The Measurement Mode Selector Switch is set

Seite 15

18 To recall memory from the DT-209X, the memory button is pressed and then released. The last measured value is displayed. The Memory Button

Seite 16

19The stored data in the tachometer can be recalled each time the memory button is pressed (M1→M2 etc.). (This is only applicable to the last Memory

Seite 17

20 The Memory Button is pressed and then released. The minimum measured value is displayed. The memory button is pressed and then released.

Seite 18

21 Clearing all the stored memory blocks requires manual deletion from the tachometer. (Example: To clear 23 blocks of memory requires erasing th

Seite 19

22LO BAT Maximum Values Allowed Unit Full range Unit Full range Non contact RPM 99,999 Contact RPM 25,000 m/min 3810.0 yd/min 4617.0 ft/min 12,50

Seite 20

23Specifications Content Model DT-209X (6-inch cir wheel), DT-209X-S12 (12-inch cir wheel) Standard mode Measurement with memory switch Average m

Seite 23

DT-209X Handheld Digital Laser Tachometer Table of Contents Section I – Handheld Tachometer • Description of Parts………………………………………………………………………….

Seite 25

DT-209X API Section Thank you for your purchase of the DT-209X handheld tachometer. Please read this section carefully before using the DT-209X soft

Seite 26 - 9999.9

Observe caution when using this software and mounting the tachometer. Serious damage to equipment is possible when misused. DT-209X API Manual CD

Seite 27

DT-209X USB Driver Installation: (WINDOWS XP) Included in your package is a USB cable. Attach USB cable to the handheld tachometer and host computer a

Seite 28

Click next. Installation process will continue. After installation is completed the following window will be displayed. Cl

Seite 29

Browse the CD content. Go to PC_API folder Windows installer package Select Windows installer package to

Seite 30

DT-209X set up wizard will open. Click “Next>” Choose installation folder where DT-209X program will be stored. 32

Seite 31

Disk Cost Space availability. Browse • Allows users to select location of the application • Default set up: C: \Program Files\NIDEC-SHIMPO\DT-20

Seite 32

Set up wizard will start the installation process. Please allow a few minutes to complete the installation process.

Seite 33

DT-209X Application Software Read this section carefully as it holds important information regarding the DT-209X software and mode windows operation

Seite 35

Main Screen Description 1. Exit – terminates the program and exits the software 2. USB Mode – Online measurement (Note: Make sure that the DT

Seite 36

5. Time Synchronize - Synchronize time with host computer for generating time stamping reports. To activate this feature click on time synchronize

Seite 37

Example: In Non-contact RPM Maximum expected speed is 1,000 RPM. Entering 1,000 in the programmable analog output will scale 1V from 0 to 1000 rpm.

Seite 38

Virtual Software LCD Display Troubleshooting USB Communication • If USB communication cannot be establish check USB cable from the tachomete

Seite 39 - DT209X for PC Windows.lnk

Unit Selector (Software) Selecting units of measure can be changed easily from the software. Provided on the main window is a virtual copy of the

Seite 40

USB Mode Screen USB mode screen display explanation Make sure that the DT-209X handheld tachometer is set to USB mode on the selector switch. Any

Seite 41

Files are saved in CSV format, which can be opened by spreadsheets. Sample of data opened in Microsoft Excel (USB Mode). Example: T

Seite 42

Sample of data saved in Excel (Standard Mode). 3. Restore – file retrieval button. Open saved file fro

Seite 43

File restore window The letter “R” identifies file restored on the list of data shown from the screen. 4. Start - measurement st

Seite 44

5. Print – Print function from the software allows transfer of images displayed from the screen to a local printer. Keystroke shortcut “ALT + P”. 6

Seite 45

1 Model DT-209X casing is similar to standard DT-207/DT-205L with addition of USB port, analog output, and selector switch. DT-209X Part

Seite 46

Confirmation screen, indicating unselected data will be erased 9. Graph – Opens graph in another window, only available in USB mode.

Seite 47

Example: The start trigger is set to 10,000. The tachometer will only start recording values when measurements exceed 10,000.

Seite 48

13. Maximum, Minimum, and Mean Value – The maximum, minimum and mean value are displayed based from the recorded data on the table.

Seite 49

15. Start and End – Displays the beginning and the end of measurements. Format: Month/ Day/ Year Time based on 24 Hours: Hour/Min/Seconds

Seite 50

18. Time – Displays synchronized time from the host computer. Format: Month/Day/Year followed by Time: Hour/Minutes Before testing it is adv

Seite 51

USB Mode Graph Screen This section describes the parts and functions of the Graph Screen under USB mode. 10 987654321 1. Cl

Seite 52

4. All – horizontal display control, time axis. Setting Explanation All It automatically sets time present while the measurements are in progres

Seite 53

Standard Mode Screen Explanation of the Standard mode screen: In this mode data can be downloaded from the DT-209X memory. Memory tab separates ea

Seite 54

1. Main – returns to the main screen (Shortcut keystroke ALT + M). 2. File Save – Downloaded data from the DT-209X is saved in CSV format. (Shortcu

Seite 55

55is selected the stored data from the DT-209X is cleared. No eval of previously stored data is possible. Selecting Cancel exits evice memory function

Seite 56

2 Parts Function 1 USB Connector Mini-USB connector for PC online measurements and data downloads. 2 Analog Output Connector 0 to 1-volt analog outp

Seite 57

7. Measurement Data – measured values stored in each memory block is displayed. 8. Block Tab – Memory block separation. Each tab corresponds to a

Seite 58

Average Mode Screen verage mode screen description and explanation. Average Mode screen initial window prior to download A Average Mode

Seite 59

1. Main – returns to the main screen. (Shortcut Keystroke ALT + M) 2. File Save – Saves downloaded data from the tachometer. File save button is ina

Seite 60

Restore File Window 4. Download – download saved data from the DT-209X. All blocks are displayed based from their occurrence. (Keystroke

Seite 61

Once “OK” is s 7. ata ane begi changes ased ormat H 8. ax, Min, A elected from the list. elected, all the Av

Seite 62

9. Blocks – Displays number of memory blocks downloaded from the tachometer. 10. HH:MM:SS. time when the data is accessed from the tachometer.

Seite 63

62 Display Hold: This feature is an enhancement to the DT-209X software, designed for users hich requires the ability to limit the amount of time the

Seite 64

ooting SectionTroublesh Problems Solution Software would not start, “Start” button anCheck mode selector switcd “Download” h. Set to USB MODE.

Seite 65

Measured value is divided by 2 There are two versions of the DT-209X, Standard Version DT-209X is set for 6 inch circumference wheel, and DT-209X-S12

Seite 66

3 Non-Contact Rotation Speed Measurement RPM Non- USB Mode(No cable connected) ON and OFF switch and block separator. For standard and average m

Seite 67

4Unit Selector Switch Multi-mode capability measures RPM, mPM, YPM, FPM, IPM and total meters, yards, feet and inches. NOTE: Select

Seite 68

5 Operation • The switch selector can be turned clockwise or counter-clockwise depending on which unit of measure is required. • The unit of measu

Kommentare zu diesen Handbüchern

Keine Kommentare