97591A FGS-VC Series Motorized Stand Operation Manual
- 5 - 4.3. Connection of PC to the stand FGS-VC can connect to PC for taking force and displacement. The software is able to be downloaded from Shim
- 6 - Select measurement mode Select Manual, Jog, Single, Continuous and Program mode according to
- 7 - 5.2. Operation mode The operation mode consists of manual and program. The mode is selected by the measurement purpose and the usage.
- 8 - 5.3. Manual operation mode The manual operation modes are MANU, JOG, SING and CONT. The mode is selected by the measurement purpose and the us
- 9 - Speed Speed can be changed by UP or DOWN button of the SPEED. The speed setting of MANU and JOG mode is common. Also the speed is able to be ch
- 10 - Parameter The parameter, which is the speed of MANU and JOG mode, is available. Pressing SET button, and the speed can be changed by UP or DOW
- 11 - 5.3.3. SING mode This mode of operation is ideal for completing one cycle between mechanical, manually adjusted distance limit stops. The tes
- 12 - Speed Speed can be changed by UP or DOWN button of the SPEED key. The speed setting of SING and CONT mode is common. Also the speed is able to
- 13 - Parameter The parameter, which is the dwell timer and the speed of pull and push, is available. Pressing SET button, the speed can be changed
- 14 - 5.3.4. CONT mode This mode of operation is ideal if the user wants the test stand to repeatedly cycle up and down continuously or for a user-
Read Manual thoroughly prior to operation. Use instrument only after reading the complete manual. Follow all safety precautions.
- 15 - Speed Speed can be changed by UP or DOWN button of the SPEED. The speed setting of SING and CONT mode is common. Also the speed is able to be
- 16 - Parameter The parameter, which is the repeat times and the dwell timer and the speed of pull and push, is available. Pressing SET button, the
- 17 - 5.4. Program operation mode 5.4.1. PROG mode This mode of operation is ideal if user wants to operate the test stand with complex programmed
- 18 - Display The example of the display under operation is shown below. Detect point Start point Start point (Dw
- 19 - Parameter The parameters are available while stopping. Pressing SET button, the parameter setting starts. The contents of the parameters setti
- 20 - Point 1 to 5 Return to “Start point” Movement Distance at P1 The parameter is the distance fr
- 21 - Force limit The stand controls to give the force less than the "Force limit". If the force limit is detected, the stand will stop im
- 22 - Parameter If you want to cancel the setting, press ZERO button. Sign of Push direction Space me
- 23 - 5.6 Chaning Engineering Units I①Change distance and speed units in the function mode. a)Function settings Pr
- 24 - 6. Message of status and error The lower limit was reached. “PUSH LMT” is blinking. If the status is abnormal, move the lower limit switc
Safety Precautions Before Installation, Operation or Maintenance, be sure to read carefully this Operation Manual and use the equipme
- 25 - Procedure of the initialization of the parameters 1. Turn off, wait one minute. 2. Press ZERO and SET button both, turn on in keeping to pre
- 26 - Table FGS-220VC M6 [mm] 3.94 1.18 7.87 5.91 M8 [mm] 0.39-1.26UNF M10 [mm] 1.77 0.79 3.94 5.51
- 27 - 8. Specifications Model FGS-220VC Capacity 100kg (1,000N, 220lb) Travel Speed 10-400mm/min (0.40-15.75”/min) Stroke 400mm (15.75”) Display Do
- 28 - Copyright© Nidec-Shimpo America Corporation 2013. All rights reserved. Product specifications are subject to change without notice.
Attention Safety Warning Disconnect from the AC outlet during any maintenance of the stand. Also, unplug when not using for long pe
Index 1. Prior to use ...
- 1 - 1. Prior to use 1.1. Procedure from the Installation of a force gauge to the measurement FGS-VC can measure various loads using Shimpo's
- 2 - 2. Names of components 3. Names and functions of the operation panel No Name Description 1 Emergency swit
- 3 - 5 MODE key Change operation modes or function settings. 6 SET key The indicated data is set when the key is pushed. 7 START key Start the progr
- 4 - 4.2. Connection of force gauge to the stand The connection and confirmation between FGS-VC and a force gauge is the following procedure.